BHO extractor closed loop
Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.
Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.
Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.
Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.
RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.
Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.
Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.
Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.
The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.
The 1400 muffle furnace reaches a maximum of 1400 C, with heating elements positioned for optimal temperature uniformity. This high temperature muffle furnace might be well-suited to a materials testing lab, or other appliions requiring very high temperature furnaces.
terminal and furnace floor plate 1.5L FP103 Specifiions FP Series Model FP103 FP303 FP313 FP413 Operating temp. range 100~1150oC Temp. control accuracy ±1.0oC (at 1150oC) Temp. fluctuation ±1.0oC (at 1150oC) Temp. distribution accuracy ±4.0ooC)
19/8/2017· When the muffle furnace is used for the first time or after long-term use, the oven must be used. Oven time should be room temperature 200 ℃ for four hours. 200 ° C to 600 ° C for four hours. When used, the maximum temperature shall not exceed the rated temperature, so as not to burn the heating element.
17/8/2019· 1. When the muffle furnace is used for the first time or after long-term deactivation, it must be oven-dried. The time of the oven should be 200 ° C for four hours at room temperature. 200 ° C to 600 ° C for four hours. When using, the furnace temperature should not exceed the rated temperature to avoid burning the heating elements.
30/12/2019· 9. After the muffle furnace is used, the power should be cut off to allow it to cool down naturally. The furnace door should not be opened immediately to prevent the furnace from being suddenly cracked. If it is used urgently, a small slit can be opened first to allow the cooling to speed up. Only when the temperature drops below 200 ° C can
660 mm. Ash-determinations, enameling, fusions, precipitate drying. 20 min. to 800°C. 3600 W. 12 l. 300°C - 1200°C. K-type thermocouple. 700 x 630 x 890 mm. Heater: Kanthal A1, expose wire heating elements, 4-side heating.
Innovative Nabertherm control technology provides for precise control as well as full documentation and remote monitoring of your processes. Our engineers apply state-of-the-art technology to improve the temperature uniformity, energy efficiency, reliability and durability of our systems with the goal of enhancing your competitive edge.
20/6/2020· Procedure for Operation of Muffle Furnace : Keep the Muffle on a leveled and firm platform. Ensure that the instrument is connected with the main power supply. Both the ON/OFF power switch and digital display illuminate. The door safety switch removes power from the heating elements when the door is open.
is operating the furnace for less than 3 hours. All furnaces consist of: 1) a vented heating chaer; 2) a temperature controller; and 3) a door interlock relay for operator safety. General usage Do not use this product for anything other than intended usage.
Muffle furnace maintenance should note: 1, when the first use of a muffle furnace again after disabling or long-term use, the oven must be carried out. The oven temperature 200 ℃ time should be four hours. 200 ℃ to 600 ℃ four hours. When used, the furnace temperature shall not exceed the maximum rated temperature, to avoid burning heating
Code. 10-D1418/D. Description. Bench-top muffle furnace 1200°C max temp. Capacity 7 lts, PID control with 30 segments programmable ramps, Digital display, temperature control by micrprocessor. Complete with stainless steel crucibles tong. 220-230V/50-60Hz/1Ph. Units. icon check. icon bag.
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. Safe Device Self diagnostic (memory error, heater disconnection, sensor error, SSR short curcuit), Electric leakage breaker, Overheat prevention device Internal dimensions WxDxH 250×300×150 mm 250×350×
Muffle furnace - Wikipedia
4.1.3 Turning off the Controller/Furnace Turn the main switch to position “O” NOTE: End all heating programs before turning the furnace off at the main switch, otherwise the controller will generate a fault message when it is turned back on. See faults/fault 4.1.4
Max. Current Power Inner Chaer Dimension (W x H x D) Product Outer Dimension (W x H x D) 546 x 668 x 790 mm Gross Dimension ( W x H x D) Net Weight Gross weight 606 x 950 x 728 mm 65 kg 85 kg 2 x 9 A 4.200 W 250 x 200 x 395 mm Model No. LMF-C50
When operating the muffle furnace, always observe the following safety precautions: • Wear insulated gloves. • Use tongs. • Never stand in front of an open furnace. •Use the supplied hearth plate on the chaer bottom. • Use safety goggles. The 650/750 • •
4) should have sufficient strength. Because when the furnace charge, lining by the impact, when affected by tilting vibration by boiling metal, slag and air erosion.lab furnaces 5) small thermal conductivity, electrical conductivity must be low. So as to ensure a
5.2 Switch “ON” the main power supply of the Muffle Furnace. 5.3 Bulb glows, which indies the power supply to the instrument. 5.4 Set the required temperature by 3 switches provided on the panel 5.4.1 Push switch 5.4.2 Two potentiometric knobs (Coarse
31/8/2020· The muffle furnace is a well insulated oven with a maximum temperature of 1100 °C. It is typically used in baking and/or sterilizing materials and glassware. It is critical to know the loion of the thermocouple and to know the melting point of whatever you are putting inside it.
Copyright © 2022. KD machinery equipment co., LTD All rights.